PART 1 - GENERAL
1.01 - Description
A. SCOPE - Provide all labor, materials, and equipment necessary to
complete the installation of prefabricated racquetball court walls and ceiling. All work
shall be done in a workmanlike manner, conforming to industry standards, including but not
limited to the following:
1. Wall and ceiling panel and related steel stud framing and/or
wood furring
2. Multi-purpose CRS Convert-A-Court Moving Glass Backwall
3. Light fixtures
4. CRS Glass walls (with Opacified Glass Design optional)
5. Doors and valuable storage compartments
6. Floor and wall markings
7. Walleyball kits
8. Floors
(WORK NOT INCLUDED)
a. HVAC components.
b. Finish trim on backwalls, common wall cutouts or corridor side
of courts
c. Electrical wiring and hook-up to light fixtures.
1.02 - Quality Assurance
A. SUPPLIER:
1. For purposes of establishing quality requirements, these
specifications are based upon the CRS Products International Panel Systems as supplied by
CRS Products International 1-800-661-4174 (416) 283-3452 Fax: (416) 283-3452, or Edmonton
(780) 484-2786 Fax: (780) 484-5827, 10021 -169 Street, Edmonton, Alberta, Canada T5P 4M9,
150 Gate 5 Road, Suite 204, Sausalito, California, U.S.A. 94965 Toll Free: 1-800-661-4174
(415) 543-4113 Fax: (415) 332-0818, Unit #1 3511 Viking Way, Richmond B.C., Canada V6V 1W1
(604) 278-7997 Fax: (604) 278-7967. Consideration will be given by the Architect to other
systems if, in his opinion, it is of equal quality. Submit information on products for
approval at least 10 days prior to bid date.
B. INSTALLER:
1. All work in conjunction with the racquetball and/or squash
courts as indicated on the drawings and as specified herein shall be installed by one
specialty contractor with no less than 15 years experience.
2. Submit a list of at least three completed projects of similar
magnitude and complexity.
1.03 - Submittals
A. Samples: Submit Samples of wall and ceiling panels.
B. Brochures: Submit three copies of suppliers brochures.
C. Shop Drawings: Submit in accordance with plans and specifications.
1.04 - Product Delivery, Storage and Handling
A. No materials shall be delivered to the jobsite until building is
completely enclosed and weathertight.
B. It is critical to the acclimation of the flooring panels that proper
humidity and temperature be maintained in the court area. Therefore, the permanent HVAC
shall be in operation prior to material arrival. Panels and flooring must be brought into
the court area five to seven days before installation under desired use conditions, which
should not be less than 13°C (58°F),
nor greater than 26°C (80°F),
and within the range of 40 to 60 percent relative humidity. Panels should never be
subjected to direct sunlight, rain, or wide variations of ambient conditions during
unloading, storage, or installation.
C. Store materials properly stacked in clean, dry, storage area.
D. Panels shall be stacked flat and delivered on pallets. After delivery,
panels shall have banding and wrap removed to allow panel to acclimate to room conditions.
E. Material not properly protected and stored and which is defaced or damaged
shall be rejected.
1.05 - Warranty
A. Material and workmanship in conjunction with racquetball and/or
squash courts shall be warranted against defects for five (5) years after installation.
Warranty covers such defects as structural failure, delamination, and workmanship when
installed and handled according to CRS Products International Specifications and
Procedures, and under normal playing conditions. CRS Products International guarantees
each panel to a corner to corner tolerance of ±0.8 mm (1/32"), an end-to-end tolerance of ±0.8
mm (1/32"), and a playing surface to playing surface
tolerance of ±0.4 mm (1/64")
when installed by CRS Products International and according to conditions set forth in
these specifications.
PART 2 - PRODUCTS
2.01 - Materials
A. Steel Framing:
1. Front walls - 152 mm (6") x 1.2 mm (18) ga. metal cee studs, 305 mm (12") o.c. with deep leg track
2. Back walls - 152 mm (6") x 1.2 mm (18) ga. metal cee studs, 305 mm (16") o.c. with deep leg track
3. Side walls - 152 mm (6") x 1.2 mm (18) ga. metal cee studs, 305 mm (16") o.c. with deep leg track
4. Common walls - 152 mm (6") x 1.2 mm (18) ga. metal cee studs, 400 mm (16") o.c. with deep leg track
5. Ceiling joists - 152 mm (6") x 1.5 mm (16) ga. metal cee studs, 400 mm (16") o.c.
Note: 92 mm (3 5/8') x 1.2 mm
(18)ga. metal cee studs may be substituted at perimeter walls if bracing can be attached
at 0.25 mm (1/4) points to
exterior building wall or mezzanine deck support.
B. FURRING: (supported by masonry walls)
1. Front walls - nominal 25.4 mm (1") x 100 mm (4") or 50.8 mm (2") x 100 mm (4") furring, 305 mm (12") o.c.
2. Side walls - nominal 25.4
mm (1") x 100 mm (4") or 50.8 mm (2") x 100 mm (4") furring, 400 mm (16") o.c.
3. Back walls - nominal 25.4
mm (1") x 100 mm (4") or 50.8 mm (2") x 100 mm (4") furring, 400 mm (16") o.c.
Note: Masonry walls shall be furnished to Racquetball court
sub-contractor straight and plumb with a maximum variation of 3
mm (1/8") in any 3 meters (10') radius Furring members shall be mechanically attached
with low velocity Hilti shot at 2; intervals. Exterior walls should be properly insulated
and vapor proofed.
C. PANELS: (UL Fire Rated Wall Panels available upon request)
1. Thickness: Squash Court front wall model #176-CRS-65 38 mm (1 7/16") thick, Squash Court side
wall and Racquetball Court. Front wall model #0118-CRS-65 - 28.6 mm (1
1/8") thick incorporating 6.35 mm (1/4") thick 1153 kg/cu m (72 lbs./cf) hardboard on both the playing and non playing sides with a 1.4 mm (0.050") thick 1362 kg/cu m (85 lbs./cf) high density
plastic laminate surface both sides for a total composite density of 1041 kg/cu m (65 lbs./cf). Side and rear
walls model #0058-CRS - 15.9 mm
(5/8") thick, 721 kg/cu m
(45 lbs./cf) composite density.
2. Dimensions: Panel sheets shall be 1219
mm (4') x 2438 mm (8') and 1219 mm
(4') x 1219 mm (4') and
installed in a staggered configuration.
3. Surface: High-pressure plastic laminate with velvet texture
finish 1.4 mm (0.050") in
thickness with an average density 1362 kg/cu m (85 lbs./cf).
4. Core: Industrial grade high density particle board of nominal 882 kg/cu m (55 lbs./cf) and 721kg/cu m (45 lbs./cf) density conforming to
commercial Standard (CS236-66).
5. Squash Court paneling must conform to International Squash
Racquet Regulation sizes of 38 mm
(1 7/16") for front walls and 28.6 mm (1 1/4") for side walls.
D. ADHESIVE:
1. Rigid set glue conforming to Federal Specifications MMM-A-188.
Attach panels to steel stud system or wood furring with screws and B.F. Goodrich P.L. 400
or W.W. Henry #217 heavy bodies structural adhesive.
E. DOOR:
1. Shall be a 45 mm (1 3/8") solid core wood door as manufactured by Stratford Industries
with full length piano hinge and covered both sides with matching plastic laminate. Soss
hinges are not acceptable. Door size 762 mm (2'6") x 2032 mm (6'8") with 254 mm (10") x 254 mm (10") viewpoint, or CRS Sports glass door C/W frame. Available in
special sizes.
F. GLASS: (5 year warranty)
1. CRS Sports glass and Multi-purpose
Convert-A-Court as manufactured and supplied by CRS Products International. Complete
glasswall systems court doors and view windows.
G. LIGHTS:
1. Fluorescent fixtures by Devoe Systems.
2. Metal halide fixtures by Abolite Lighting, with heat and
impact resistant prismatic glass lenses.
H. FLOORS
1. Concrete sub-floor shall be furnished to the racquetball court
sub-contractor broom-clean and steel troweled smooth, and level with a maximum variation
of 3 mm (1/8") in any 3 mm (10') radius. Any leveling required to
meet this tolerance shall be the responsibility of the general contractors or owners.
2. CRS Products International provides and installs wood floor
systems utilizing MFMA northern hard maple.
I. TELL-TALES (Game Line Mouldings):
1. Squash court tell-tales (delete if not applicable) - 0.60 mm (16) gauge steel and appropriate
dimension size. Game Line Moulding (14) gauge.
J. ACCESSORIES
1. Valuable storage compartments (valu box) as manufactured by
CRS Products International.
2. CRS Walleyball Set interior or Racquet Ball Court as supplied
and installed by CRS Products International.
Part 3 - EXECUTION
3.01 - Inspection
A. Inspect court area to be ensure conditions as set forth in these
specifications have been adhered to.
B. Inspect concrete sub-floors and masonry walls for proper tolerance and
dryness. Discrepancies should be reported to the general contractor and architect in
writing. Correction of such is the responsibility of others.
C. Masonry walls shall be free of protruding mortor by masonry contractor.
3.02 - Installation
A. Install metal studs and/or furring in width and spacing in
locations as shown on plans. Studs shall be plumb and corners square. Attach aluminum
spline to studs with no fewer than four (4) screws per panel edge. Each stud shall receive
a ribbon of construction adhesive the full length of the panel. No plugs shall be used and
no screwheads shall show.
B. Clean-up all debris caused by work in this section and remove same from
premises.
Manufacturer reserves the right to change design or specifications to improve product or